Model No.: OM
Production Capacity: 500set/month
Delivery Date: 12-25 business days
Feature: Patent pending turnover tec...
Working electric power: 220v,50-60Hz.Or customized
Customized: Accept
Means of Transport: Ocean,Land,Air
Packing: Plywood box for export
Brand Name: C&H
Include: 3 parts
Factory: Original factory

Medical Gas Manifold System
Medical Gas Source Equipment with Cylinders
Medical Gas Regulators System
For Medical Gas Pipeline System
Customized

Oxygen Manifold System As Medical Gas Pipeline Equipment

More details~

 Before, the medical gases in hospitals are stored and supplied by separated medical gas cylinders. The separated medical 

gases (including oxygen, compressed air, nitrous oxide, carbon dioxide, etc.) cylinders are put in the operating theatres, 

wards, etc. By this way, it is not so convenient and safe for medical staff to use.

Now, more and more hospitals adopt the Medical Gas Pipeline System for medical gases supplying. With Medical Gas

Pipeline System, it achieve to supply different medical gases uninterrupted and safely

With Medical Gas Pipeline System, the oxygen in cylinders is not the oxygen source any more. However, as a back-up 

oxygen source, Oxygen Cylinders (with pressed oxygen gases inside) controlled by medical gas manifold system is still a

necessary equipment for medical oxygen supplying in hospitals. Also, for some small hospitals, Medical Oxygen Manifold

 System is a more economical medical source equipment than the Medical Oxygen Generator System.

Function of a Manual Dual Lines Medical Oxygen Manifold System

1.To connect several different medical oxygen cylinders together: the Manual Dual Lines Oxygen Manifold System

connected and manage several pieces of oxygen cylinders, to collect the medical oxygen gas in different oxygen 

cylinders and then supply to medical oxygen pipeline;

2. To regulate medical oxygen gas pressure: medical oxygen gas in cylinders is in a high pressure (usually the initial 

pressure is 15MPa). This high pressure oxygen gas can not be supply to patients or other medical equipment directly. 

Before it supplied, the pressure must be regulated to a much lower one. The Manual Dual Lines Medical Oxygen 

Manifold System achieve to regulate the oxygen gas pressure;

3.To manage oxygen cylinders in different lines: medical oxygen cylinders are connected with the Manual Dual Lines 

Oxygen Manifold System's different lines. Usually, these two lines are controlled separated, and they do not supply 

medical oxygen gas one the same time. After the medical oxygen cylinders in one line are empty, users can shut off 

this line, and turn on another line. The empty oxygen cylinders can be discharged and to be refilled. To repeat these processes can ensure uninterrupted medical oxygen supplying to hospital oxygen pipeline

Parts of a Manual Dual Lines Medical Oxygen Manifold System

(1) Medical Oxygen Regulators: to regulate oxygen gas pressure;

(2) One-Way Valves / Non-Returning Valves: to avoid oxygen gas return to cylinders;

(3) Pressure Gauges: to show oxygen gas pressure in different section;

(4) Pigtails / Stainless Steel High Pressure Hoses: to connect oxygen cylinders;

(5) Pipes: to connect different parts;

As a manufacturer of medical gas pipeline system equipment and materials manufacturer, Ningbo JianZhiKang Medical 

Equipment Co., Ltd. produce and supply different models of Manual Dual Lines Medical Oxygen Manifold Systems.

General Features

1. Operating and line regulators provided with relief valve;

2. Pressure switch with dry contacts pressure sensor to indicate reserve in use;

3. One-Way Valves / Non-Return Valves;

4. Customize for different quantity of oxygen cylinders;

5. Customize for different standards of oxygen cylinder valves;

Wall Type Cylinder Brackets (to be ordered separately);

Specifications:

1. Safe Input Pressure: 20.0MPa;

2. Service Input Pressure: 15.0MPa; 

3. Service Output Pressure: 0.4~0.8MPa adjustable;

4. Service Output Flow Rate: ≤120Nm3/hour;

We also produce and supply Manual / Automatic Medical Gas Manifold Systems for Nitrous Oxide, Compressed Air, 

Carbon Dioxide, etc.


Medical Oxygen Manifold System

What advantage do we have:

1, Original Manufacturer: all the Gas Outlets and the Gas Outlet Adapters are produced by our own factory;

2, Certificate: ISO13485 (issued by SGS), CE (issued by SGS);

3, Producing Equipments: the producing equipments for the Gas Outlets include CNC (8 sets), Stamping Machine (10 sets), Automatic Welding Machine (2 sets), Metal Treatment Set (1 set, large scale), etc.;

4, Material: all the products are made of original material;

5, Quality: all parts are produced by ourselves with strict quality controlling;

6, Cost: we have competetive cost advantage because of the scale economy;

7, Perfect appearance of the gas outlets and adapters;


Mr. Alec Chan
skype Mr. Alec Chan
Export Director
Tel: 86-20-28981316
Fax: 86-20-28981384
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

Guangzhou C&H Medical Co.,Ltd. [China (Mainland)]


Business Type:Manufacturer, Trading Company, Service
City: Guangzhou
Province/State: Guangdong
Country/Region: China (Mainland)

Skype Online Service:   skype

You May Like: